Metric Bolt Size, Strength & Torque
Look up the pitch, stress area, proof and tensile load and recommended tightening torque for metric bolts by size and grade, free online.
इस कैलकुलेटर के बारे में
Metric coarse-thread data (ISO 898-1): tensile stress area A_s and strength grades 4.6, 8.8, 10.9, 12.9. Proof load = A_s × proof stress; tensile load = A_s × tensile strength. Tightening torque T ≈ K·d·F with K ≈ 0.2 (dry, plain) at 75% of proof load for a reusable joint. Tap drill ≈ nominal diameter − pitch.