Open Channel Flow (Manning)
Calculate flow rate, velocity and Froude number in a rectangular or trapezoidal open channel with Manning's equation, free online.
About this calculator
Manning: Q = (1/n)ยทAยทR^(2/3)ยทS^(1/2) where A is the flow area, R = A รท wetted perimeter, S the bed slope and n the roughness (0.012 smooth concrete, 0.030 earth channel, 0.035 natural stream). Froude number Fr = v รท โ(gยทA/T): below 1 is subcritical (tranquil) flow.